CO2 neutral production
Quality "Made-in-Germany"
Very high availability
More than 2.000 EOAT components

HEU 16 A XY Mounting Adapter for XY-Stroke Unit

Part No.: 1-753-12-00
Compatible to
Connection thread
Part No.: 1-753-12-00
Description Part No. Option
HEU 16 A XY Mounting Adapter for XY-Stroke Unit Compatible to: HEU 16; HEU L 16, Connection thread: M6 HEU 16 A XY Mounting Adapter for XY-Stroke Unit 1-753-12-00 Compatible to: HEU 16; HEU L 16, Connection thread: M6
  • e.g. for even more flexibility in pick-and-place robot hands (material injection)
  • easy to assemble and spacesaving design
  • two HEU 16 can be adapted to an XY stroke unit
  • angle of the X-stroke can be infinitely adjusted by an integrated centering +/- 45 °
  • both stroke units are connected positively and form locking to the adapter
Material: Aluminium
Weight: 158.64 g
Downloads and 3D-data are only available to logged in users.

Products matching the article

HEU 16-50 Stroke Unit with Piston-Ø 16 mm
for delivery of various components - numerous mounting accessories allow various applications such as positioning textiles or demoulding partspneumatic Stroke Unit with piston diameter 16 mm (doubleacting)one cylinder and two guides Stroke Unit can absorb lateralforces and momentsstroke infinitely adjustablemaximum air pressure is 6 bar, use dry and filtered air onlyMonitoring: monitoring of end psoitions (inductive) with IEK 8 or IES 8Accessories e.g.:X-ProfileHEU 16 A XY - Adapter GP-HEU 16 - adapter plate HEUKN-HEU 16 - adapter for 20 mm clampsAE-HEU 16 - adapter HEUAU-HEU 16 - adapter HEUAP-HEU 16 - adapter HEU
HEU 16-25 Stroke Unit with Piston-Ø 16 mm
for delivery of various components - numerous mounting accessories allow various applications such as positioning textiles or demoulding partspneumatic Stroke Unit with piston diameter 16 mm (doubleacting)one cylinder and two guides Stroke Unit can absorb lateralforces and momentsstroke infinitely adjustablemaximum air pressure is 6 bar, use dry and filtered air onlyMonitoring: monitoring of end psoitions (inductive) with IEK 8 or IES 8Accessories e.g.:X-ProfileHEU 16 A XY - Adapter GP-HEU 16 - adapter plate HEUKN-HEU 16 - adapter for 20 mm clampsAE-HEU 16 - adapter HEUAU-HEU 16 - adapter HEUAP-HEU 16 - adapter HEU
HEU 16-80 Stroke Unit with Piston-Ø 16 mm
for delivery of various components - numerous mounting accessories allow various applications such as positioning textiles or demoulding partspneumatic Stroke Unit with piston diameter 16 mm (doubleacting)one cylinder and two guides Stroke Unit can absorb lateralforces and momentsstroke infinitely adjustablemaximum air pressure is 6 bar, use dry and filtered air onlyMonitoring: monitoring of end psoitions (inductive) with IEK 8 or IES 8Accessories e.g.:X-ProfileHEU 16 A XY - Adapter GP-HEU 16 - adapter plate HEUKN-HEU 16 - adapter for 20 mm clampsAE-HEU 16 - adapter HEUAU-HEU 16 - adapter HEUAP-HEU 16 - adapter HEU
HEU 16-100 Stroke Unit with Piston-Ø 16 mm
for delivery of various components - numerous mounting accessories allow various applications such as positioning textiles or demoulding partspneumatic Stroke Unit with piston diameter 16 mm (doubleacting)one cylinder and two guides Stroke Unit can absorb lateralforces and momentsstroke infinitely adjustablemaximum air pressure is 6 bar, use dry and filtered air onlyMonitoring: monitoring of end psoitions (inductive) with IEK 8 or IES 8Accessories e.g.:X-ProfileHEU 16 A XY - Adapter GP-HEU 16 - adapter plate HEUKN-HEU 16 - adapter for 20 mm clampsAE-HEU 16 - adapter HEUAU-HEU 16 - adapter HEUAP-HEU 16 - adapter HEU
HEU 16-125 Stroke Unit with Piston-Ø 16 mm
for delivery of various components - numerous mounting accessories allow various applications such as positioning textiles or demoulding partspneumatic Stroke Unit with piston diameter 16 mm (doubleacting)one cylinder and two guides Stroke Unit can absorb lateralforces and momentsstroke infinitely adjustablemaximum air pressure is 6 bar, use dry and filtered air onlyMonitoring: monitoring of end psoitions (inductive) with IEK 8 or IES 8Accessories e.g.:X-ProfileHEU 16 A XY - Adapter GP-HEU 16 - adapter plate HEUKN-HEU 16 - adapter for 20 mm clampsAE-HEU 16 - adapter HEUAU-HEU 16 - adapter HEUAP-HEU 16 - adapter HEU
HEU 16-160 Stroke Unit with Piston-Ø 16 mm
for delivery of various components - numerous mounting accessories allow various applications such as positioning textiles or demoulding partspneumatic Stroke Unit with piston diameter 16 mm (doubleacting)one cylinder and two guides Stroke Unit can absorb lateralforces and momentsstroke infinitely adjustablemaximum air pressure is 6 bar, use dry and filtered air onlyMonitoring: monitoring of end psoitions (inductive) with IEK 8 or IES 8Accessories e.g.:X-ProfileHEU 16 A XY - Adapter GP-HEU 16 - adapter plate HEUKN-HEU 16 - adapter for 20 mm clampsAE-HEU 16 - adapter HEUAU-HEU 16 - adapter HEUAP-HEU 16 - adapter HEU
HEU 16-200 Stroke Unit with Piston-Ø 16 mm
for delivery of various components - numerous mounting accessories allow various applications such as positioning textiles or demoulding partspneumatic Stroke Unit with piston diameter 16 mm (doubleacting)one cylinder and two guides Stroke Unit can absorb lateralforces and momentsstroke infinitely adjustablemaximum air pressure is 6 bar, use dry and filtered air onlyMonitoring: monitoring of end psoitions (inductive) with IEK 8 or IES 8Accessories e.g.:X-ProfileHEU 16 A XY - Adapter GP-HEU 16 - adapter plate HEUKN-HEU 16 - adapter for 20 mm clampsAE-HEU 16 - adapter HEUAU-HEU 16 - adapter HEUAP-HEU 16 - adapter HEU
HEU L 16-25 Stroke Unit with Piston-Ø 16 mm
for delivery of various components - numerous mounting accessories allow various applications such as positioning textiles or demoulding partsWeight reduction through aluminum shafts and plastic plain bearings up to 30% lighter than standard lifting units (HEU) with steel shafts Identical in dimensions to HEUpneumatic Stroke Unit with piston diameter 16 mm (doubleacting)one cylinder and two guides Stroke Unit can absorb lateralforces and momentsstroke infinitely adjustablemaximum air pressure is 6 bar, use dry and filtered air onlyMonitoring: monitoring of end positions (inductive) with IEK 8 or IES 8Accessories e.g.:X-ProfileHEU 16 A XY - Adapter GP-HEU 16 - adapter plate HEUKN-HEU 16 - adapter for 20 mm clampsAE-HEU 16 - adapter HEUAU-HEU 16 - adapter HEUAP-HEU 16 - adapter HEU
HEU L 16-50 Stroke Unit with Piston-Ø 16 mm
for delivery of various components - numerous mounting accessories allow various applications such as positioning textiles or demoulding partsWeight reduction through aluminum shafts and plastic plain bearings up to 30% lighter than standard lifting units (HEU) with steel shafts Identical in dimensions to HEUpneumatic Stroke Unit with piston diameter 16 mm (doubleacting)one cylinder and two guides Stroke Unit can absorb lateralforces and momentsstroke infinitely adjustablemaximum air pressure is 6 bar, use dry and filtered air onlyMonitoring: monitoring of end positions (inductive) with IEK 8 or IES 8Accessories e.g.:X-ProfileHEU 16 A XY - Adapter GP-HEU 16 - adapter plate HEUKN-HEU 16 - adapter for 20 mm clampsAE-HEU 16 - adapter HEUAU-HEU 16 - adapter HEUAP-HEU 16 - adapter HEU
HEU L 16-80 Stroke Unit with Piston-Ø 16 mm
for delivery of various components - numerous mounting accessories allow various applications such as positioning textiles or demoulding partsWeight reduction through aluminum shafts and plastic plain bearings up to 30% lighter than standard lifting units (HEU) with steel shafts Identical in dimensions to HEUpneumatic Stroke Unit with piston diameter 16 mm (doubleacting)one cylinder and two guides Stroke Unit can absorb lateralforces and momentsstroke infinitely adjustablemaximum air pressure is 6 bar, use dry and filtered air onlyMonitoring: monitoring of end positions (inductive) with IEK 8 or IES 8Accessories e.g.:X-ProfileHEU 16 A XY - Adapter GP-HEU 16 - adapter plate HEUKN-HEU 16 - adapter for 20 mm clampsAE-HEU 16 - adapter HEUAU-HEU 16 - adapter HEUAP-HEU 16 - adapter HEU
HEU L 16-100 Stroke Unit with Piston-Ø 16 mm
for delivery of various components - numerous mounting accessories allow various applications such as positioning textiles or demoulding partsWeight reduction through aluminum shafts and plastic plain bearings up to 30% lighter than standard lifting units (HEU) with steel shafts Identical in dimensions to HEUpneumatic Stroke Unit with piston diameter 16 mm (doubleacting)one cylinder and two guides Stroke Unit can absorb lateralforces and momentsstroke infinitely adjustablemaximum air pressure is 6 bar, use dry and filtered air onlyMonitoring: monitoring of end positions (inductive) with IEK 8 or IES 8Accessories e.g.:X-ProfileHEU 16 A XY - Adapter GP-HEU 16 - adapter plate HEUKN-HEU 16 - adapter for 20 mm clampsAE-HEU 16 - adapter HEUAU-HEU 16 - adapter HEUAP-HEU 16 - adapter HEU
IEK 8 PNP Sensor, with 3 m cable
inductive proximity switch sensor is used e.g. for standard monitoring on ASS grippers (GRZ 20-16, GRZ 32, GRZ 10-12) and stroke units (HEU / HEU-L) PNP and NPN switching available Initiator can be fixed with an M3 screw connection M8 3-pinM3 hexagon socket screw not included
IEK 8 NPN Sensor, with 3 m cable
inductive proximity switch sensor is used e.g. for standard monitoring on ASS grippers (GRZ 20-16, GRZ 32, GRZ 10-12) and stroke units (HEU / HEU-L) PNP and NPN switching available Initiator can be fixed with an M3 screw connection M8 3-pinM3 hexagon socket screw not included
IES 8 PNP Sensor, with plug
inductive proximity switch sensor is used e.g. for standard monitoring on ASS grippers (GRZ 20-16, GRZ 32, GRZ 10-12) and stroke units (HEU / HEU-L) PNP and NPN switching available Initiator can be fixed with an M3 screw connection M8 3-pinM3 hexagon socket screw not included
IES 8 NPN Sensor, with plug
inductive proximity switch sensor is used e.g. for standard monitoring on ASS grippers (GRZ 20-16, GRZ 32, GRZ 10-12) and stroke units (HEU / HEU-L) PNP and NPN switching available Initiator can be fixed with an M3 screw connection M8 3-pinM3 hexagon socket screw not included